AS Series |
AS Series
Current Sensors are designed as a low cost method of controlling, monitoring or measuring AC currents. The sensors serve as feedback elements between the output and pulse control circuitry providing accurate regulation of switch mode power supplies.
Features
Manufactured in ISO-9000 approved facility
Aplications
Isolated current feed-back signal in Switch Mode Power Supplies - Motor
current load/overload - Lighting Switch Controls Ultra-sound current -
High resolution sonar current - Isolated bi-directional current sensor
with full wave bridge rectifier.
Electrical Specifications at 25°C
Inductor
Part Number |
Prim./Sec
Ratio |
Lsec
(1)
(mH Min.) |
DCRsec
Ohms (Max) |
Sec.
Term. (2)
Resistance Ohms (Nom.) |
Isec
(3) Max. |
Volt-µS
(4) Max. |
Schematic
|
| AS-100 AS-101 AS-102 AS-103 AS-104 |
1/50 1/100 1/200 1/300 1/500 |
6 25 100 250 700 |
0.6 1.1 4.5 10.0 25.0 |
50 100 200 300 500 |
300mA 150mA 75mA 50mA 30mA |
175 350 700 900 1500 |
|
| AS-110 AS-111 AS-112 AS-113 AS-114 |
1/50CT 1/100CT 1/200CT 1/300CT 1/500CT |
6 25 100 250 700 |
0.3/0.3 0.55/0.55 2.25/2.25 5.0/5.0 12.5/12.5 |
25+25 50+50 100+100 150+150 250+250 |
300mA 150mA 75mA 50mA 30mA |
175 350 700 900 1500 |
![]() |
Notes:
1) Lsec : Secondary inductance tested at l0kHz and l.0mV 2) This nominal termination resistance value will yield approximately 1.0V of output for each amp of current in a single turn sense line. The output Voltage/Ampere of these devices can be increased or decreased linearly over a restricted temperature range by adjusting the terminating resistance. 3) The Isec value corresponds to a maximum primary current of 15 Amp-turns RMS 4) VmS = Rt x ls x (1/2F) Rt (Ohms): Recommended Terminating Resistance Is (A): Secondary Current F (Hz): Frequency 5) Operating Temperature Range: -40°C to +120°C 6) Pin 2 is on Center-Tapped (CT) versions only |
![]() |
Electrical Specifications at 25°C
Transformer Number Type 1 |
Part Type 2 |
Prim./Sec |
Lsec (1) |
DCRsec |
Sec. Term. (2) |
Isec |
Volt-µS |
Schematic |
| AS-200 AS-201 AS-202 |
AS-300 AS-301 AS-302 |
1/50 1/100 1/200 |
5 20 80 |
0.65 1.30 4.50 |
50 100 200 |
300mA 150mA 75mA |
175 350 700 |
|
| AS-210 AS-211 AS-212 |
AS-310 AS-311 AS-312 |
1/50CT 1/100CT 1/200CT |
5 20 80 |
0.65 1.30 4.50 |
25+25 50+50 100+100 |
300mA 150mA 75mA |
175 350 700 |
|
| AS-320 AS-321 AS-322 |
1/50CT 1/100CT 1/200CT |
5 20 80 |
0.65 1.30 4.50 |
50 100 200 |
300mA 150mA 75mA |
175 350 700 |
||
| AS-330 AS-331 AS-332 |
1/50CT 1/100CT 1/200CT |
5 20 80 |
0.65 1.30 4.50 |
25+25 50+50 100+100 |
300mA 150mA 75mA |
175 350 700 |


Features:
Meets requirements of IEC 950 and VDE norms
UL 94-V0 recognized materials
Operating frequency range from 20 kHz
Operating Temperature Range: -40 °C to +120 °C
Primary to secondary isolated to 4000 VAC
Primary current rating to 80 Amps
|
Inviate a sales@talema.it
un messaggio di posta elettronica contenente domande sui prodotti di Vostro